KBLV0225TG Sterilizing grade capsule filter 5inch KB Series

KBLV0225TG Sterilizing grade capsule filter 5inch KB Series

Eternalwater KB series--KBLV0225TG Sterilizing grade capsule filter 5inch KB Series, which can be applied in biological process steps. Satisfying the application from small experiment to large-scale production, it has excellent filtration performance and reliable sterilization guarantee.
  • Industry Application
  • Bacterial removal filtration for large and small volume infusions
    Bacterial removal filtration for Vaccines, Biologicals and Antibiotics
    Bacterial removal filtration for serum and plasma separation
    Bacterial removal filtration for cell culture media
    Bacterial removal filtration for diagnostic reagents and preparations containing proteins, vitamins and preservatives
    Disposable stock solution sterile filtration
    Buffer solution filtration
  • DOWNLOAD
  • INQUIRY NOW
PRODUCT DESCRIPTION
  • Nominal size:
  • 20inch | 10inch | 5inch
  • Outer diameter:
  • 85mm | 84mm | 84mm
  • Total length:
  • 569mm | 319mm | 220mm
  • Filtration area:
  • 12000cm2 | 6000cm | 3000cm
  • Housing material:
  • Polypropylene
  • Center pole material:
  • Polypropylene
  • Support layer material:
  • Polypropylene
  • Vent O-ring Material:
  • Silicone
  • Vent /Drain Outlet Diameter:
  • Φ6mm
  • Maximum Operating Pressure Difference:
  • 4 bar (58 psi) at 25°C
  • Housing pressure:
  • 5.5 bar (80 psi) at 25°C
  • Sterilization:
  • Can be sterilized by Gamma radiation up to 45KGy Can be sterilized by high-pressure steam at 126°C for 30 minutes three times (in-line steam sterilization is not available)
  • Bacterial Endotoxin:
  • According to the bacterial endotoxin test method stipulated in the general rule (1143) of the Chinese Pharmacopoeia 2020 edition. As determined by Limulus reagent (LAL), the aqueous extract content is < 0.25 EU/mL
  • Microbial Challenge Test:
  • >107cuf/cm2; according to ASTM® test method passed Pseudomonas diminuta (B. diminuta) ( ATCC® 19146)
  • Biosecurity:
  • All materials meet USP <88> Reaction Test Standards for Plastic Materials Class VI-70°C
  • TOC/Conductivity:
  • TOC value≤0.5mg/L, conductivity value≤1.3us/cm. According to the Chinese Pharmacopoeia 2020 Edition, the general rule (0682) the determination method of total organic carbon in pharmaceutical water and the general rule (0681) the determination method of the conductivity of pharmaceutical water
  • Cleanliness:
  • According to the light inspection method stipulated in the general rules (0904) of the Chinese Pharmacopoeia 2020 edition, no fibers and other visible foreign matter were detected in the filtrate
  • Integrity Test:
  • Bubble point, diffusion flow, water intrusion; please consult the sales engineer of Eternalwater Company for detailed parameters
Ordering Information
  • Series
  • KB Series
  • Membrane Material
  • S=Hydrophilic
  • PES ST=Hydrophobic PES
  • T=Hydrophobic PTFE
  • LT=Hydrophilic PTFE
  • V=Hydrophobic PVDF
  • LV=Hydrophilic PVDF
  • M=MCE
  • N=Nylon
  • P=PP
  • Removal Rating
  • 005=0.05μm
  • 010=0.10μm
  • 020=0.20μm
  • 045=0.45μm
  • 065=0.65μm
  • 080=0.80μm
  • 100=1.0μm
  • 120=1.20μm
  • 020010=0.20+0.10μm
  • 020020=0.22+0.20μm
  • 045020=0.45+0.20μm
  • 065020=0.65+0.20μm
  • 065045=0.65+0.45μm
  • 080020=0.80+0.20μm
  • 120020=1.20+0.20μm
  • Length
  • 5=5inch
  • 10=10inch
  • 20=20inch
  • End Cap Type
  • T=TC50
  • Sterilized Form
  • G=Resistance to Gamma Radiation Sterilization
  • Z=Autoclave only
  • W=Sterile type
  • Packing
  • 1=1 Pcs/Box
    • Subscribe for Join Us!



    • Join us and get detail information,technical parameter and new products etc.
    CopyRight © Hangzhou Eternalwater Filtration Equipment Co., Ltd. 2002-2024