High-removal rating polypropylene (PP) pleated filter cartridge

High-removal rating polypropylene (PP) pleated filter cartridge

Eternalwater EAP Series--Polypropylene fiber membrane is adopted, and the microfiber membrane has high removal rating and high retention rate. Pre-filtration cartridges widely used in the bio-pharmaceutical industry.
  • Product features
  • High removal rating, high retention rate of 98%
    No fiber shedding
    Pure polypropylene material, widely chemical compatibility
    High flow rate, low pressure drop
  • Industry Application
  • Pre-filtration of bio-pharmaceutical water
    Pre-filtration of colloidal material
    Pre-filtration of API
    Filtration of fermentation solution
    Pre-filtration of preparing solution system
  • DOWNLOAD
  • INQUIRY NOW
PRODUCT DESCRIPTION
  • Nominal size:
  • 0.5inch | 1inch
  • Outer diameter:
  • 67mm
  • Total length:
  • 98.5mm | 120mm
  • Filtration area:
  • 200cm2 | 400cm2
  • Housing material:
  • Polypropylene
  • Center pole material:
  • Polypropylene
  • Support layer material:
  • Polypropylene
  • Vent O-ring Material:
  • Silicone
  • Vent /Drain Outlet Diameter:
  • Φ4mm
  • Maximum Operating Pressure Difference:
  • 4 bar (58 psi) at 25°C
  • Housing pressure:
  • 5.5 bar (80 psi) at 25°C
  • Sterilization:
  • Can be sterilized by Gamma radiation up to 45KGy Can be sterilized by high-pressure steam at 126°C for 30 minutes three times (in-line steam sterilization is not available)
  • Bacterial Endotoxin:
  • According to the bacterial endotoxin test method stipulated in the general rule (1143) of the Chinese Pharmacopoeia 2020 edition. As determined by Limulus reagent (LAL), the aqueous extract content is < 0.25 EU/mL
  • Microbial Challenge Test:
  • >107cuf/cm2; according to ASTM® test method passed Pseudomonas diminuta (B. diminuta) ( ATCC® 19146)
  • Biosecurity:
  • All materials meet USP <88> Reaction Test Standards for Plastic Materials Class VI-70°C
  • TOC/Conductivity:
  • TOC value≤0.5mg/L, conductivity value≤1.3us/cm. According to the Chinese Pharmacopoeia 2020 Edition, the general rule (0682) the determination method of total organic carbon in pharmaceutical water and the general rule (0681) the determination method of the conductivity of pharmaceutical water
  • Cleanliness:
  • According to the light inspection method stipulated in the general rules (0904) of the Chinese Pharmacopoeia 2020 edition, no fibers and other visible foreign matter were detected in the filtrate
  • Integrity Test:
  • Bubble point, diffusion flow, water intrusion; please consult the sales engineer of Eternalwater Company for detailed parameters
Ordering Information
  • Series
  • EAP Series
  • Micron Rating
  • 010=0.10μm
  • 020=0.20μm
  • 045=0.45μm
  • 065=0.65μm
  • 100=1.00μm
  • 500=5.00μm
  • End cap type
  • J1=222/Fin
  • J2=222/Flat
  • J3=226/Fin
  • J4=226/Flat
  • J5=DOE
  • Length
  • 05=5"
  • 10=10"
  • 20=20"
  • 30=30"
  • 40=40"
  • O-ring
  • S=Silicone
  • E=EPDM
  • V=Viton
  • core
  • A=PP core
  • B=PP Cage material + End cap type lined with stainless steel
    • Subscribe for Join Us!



    • Join us and get detail information,technical parameter and new products etc.
    CopyRight © Hangzhou Eternalwater Filtration Equipment Co., Ltd. 2002-2024